1.2 GENERAL DESCRIPTION
1.2.1 Apex Unit
The apex unit (see Figure 1-2) includes the condensing
section, evaporator section, Micromax electronics, and
the Fresh Air System. All components are accessible by
lifting the top cover. Descriptions of the systems are
provided in the following sub paragraphs.
1
2
3
4
5
6
7
8
10
11
9
1. Top Cover
2. Gas Spring (2)
3. Condenser Section (See Figure 1-3)
4. Evaporator Section (See Figure 1-4)
5. Base
6. Fresh Air System
7. Gas Spring Support (2)
8. Lock (2)
9. Serial Plate
10. Hinge
11. Condenser Fan Grille (4-GR45,
6-GR60)
12. Front Drain (2)*
13. Intermediate Drain (2)*
14. Evaporator Rear Drain (2)*
15. Condenser Rear Drain (2)*
* Not Shown
Figure 1-2. Apex Unit Components
(GR-60 Shown)
1.2.2 Condensing Section
The condensing section (Figure 1-3) includes the
condenser coils, fan and motor assemblies, filter-drier,
receiver, liquid line solenoid valve, service valves, and
an ambient temperature sensor.
The condenser coils provide heat transfer surface for
condensing refrigerant gas at a high temperature and
pressure into a liquid at high temperature and pressure.
The condenser fans circulate ambient air across the
outside of the condenser tubes at a temperature l ower
than refri gerant circulating i nside the tubes; this results
in condensation of the refrigerant into a liquid. The
filter-drier removes moisture and debris from the liquid
refrigerant before it enters the thermostatic expansion
valve in the evaporator assembly.