62-11175 COMFORTPRO SERVICE MANUAL
1-5
H
OURS
0
0000
A
PU
PLEASE WAIT
APU STARTING
O
FF
OFF
WARNING
Do not start the APU when the enclosure
cover is removed. Operating with the
cover off may result in injury and/or death.
P
ress and release once.
The display shows "PLEASE WAIT – APU
STARTING" and flashes.
When stops flashing, then the APU
has started successfully.
The APU startup sequence consists of
20 seconds of glowing (30 seconds when
the ambient temperature is below -5°C or
23°F) and up to 10 seconds of cranking.
If the sequence fails, "RESTARTING"
appears for six seconds. Then the
startup sequence automatically repeats
up to five times or until the APU starts.
If "CRANK LIMIT" appears, see
Troubleshooting section.
H
OURS
0
0000
APU
RESTARTING
OFF
OFF
HOURS
00000
APU
CRANK LIMIT
OFF
OFF
WARNING
When the APU is about to start, a buzzer
sounds. Make sure no one is standing
near the APU or touching it.
1.2.1 Starting the APU "One Touch Start"
Press
.
The APU will stop. The display
shows .
Make sure to shut down HVAC before
stopping APU!
1.2.2 Stopping the APU
1.2 MANUAL OPERATIONS
1 Press to activate the heater.
The display shows "HEAT LOW".
The heater will turn on only if the
temperature is too low (to adjust the
temperature, see below). When the
heater is on, appears.
2 Press again to switch between
high and low heat to heat the truck
bunk more or less quickly. In "HEAT
HIGH" mode, the power outlet is
disabled and the display indicates .
The heat will turn off when the desired
temperature is reached.
3 Press to deactivate heating.
HOURS
00000
APU
CH
HEAT HIGH
OFF
NOTICE
The heat mode will not function if the
temperature is higher than 29.5°C (85°F).
1.2.3 Turning the Heater ON/OFF
Pc6000 do you know what model mine would be is there more than one model