62-11175 COMFORTPRO SERVICE MANUAL
3-16
3.9.6 Fuel Solenoid Troubleshooting
I
f a faulty fuel solenoid is suspected (per diagnostic flow chart 62-11409) then use
instructions below for troubleshooting.
U
nplug the solenoid connector and check the resistance between the following terminals
with a DVOM.
White to Black = 0.3 0.7 Ohm
Red to Black = 13 25 Ohm
White to Red = Open (OL)
If the resistance is out of range then replace the fuel solenoid.
If the resistance measured is within range then check the fuel solenoid circuit in the APU
controller for open or close.
If resistance is within range and there are no opens or shorts in the circuit in the APU
controller, then replace the APU controller.