© Carrier Corporation 2014 Form 50PT-1APD
Single-package horizontally and verti-
cally mounted water source heat
pumps with electronic controls offer:
Two-stage unloading scroll
compressor
Variable speed blower motor
Exclusive double spring and
grommet compressor isolation for
ultra-quiet operation
Available mute package for quieter
operation
Performance certified to ARI/ISO
13256-1
Flexible and reliable multiple
protocol WSHP Open controller can
use BACnet
*
, Modbus
, N2, and
LON (with a separate card)
protocols for integrating energy
efficiency and precise unit control
(field-installed accessory)
Hot gas reheat (HGR) available for
dehumidification capability
Optional tin-plated copper tubing
and polymer coated aluminum fin
evaporator coil available
Non-ozone depleting Puron
refrigerant (R-410A)
Features/Benefits
Carrier’s Aquazone two-stage
water source heat pump
(WSHP) with Puron
refrigerant (R-410A) is a high
quality, ultra-efficient solution
for all boiler/tower and
geothermal design
applications.
Operating efficiency
Carrier WSHPs are designed for quali-
ty and high performance over a life-
time of operation. Two-stage WSHP
models with Puron refrigerant offer
cooling EERs (Energy Efficiency Ra-
Aquazone™
50PTH, PTV024-070
Two-Stage Water Source Heat Pumps
with Puron
®
Refrigerant (R-410A)
*For units purchased on or after May 12, 2014.
2 to 6 Nominal Tons
Advance
Product
Data*
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Features/Benefits

© Carrier Corporation 2014 Form 50PT-1APDSingle-package horizontally and verti-cally mounted water source heat pumps with electronic controls offer:•

Page 2 - Features/Benefits (cont)

10***50PTH024-070 UNITS SUPPLY AIR CONFIGURATION - STRAIGHT THROUGHDimensions (cont)

Page 3

1150PTH024-070 UNITS HANGING BRACKET SPECIFICATIONS

Page 4

12SUPPLY AIRDUCT FLANGESRETURN AIRDUCT FLANGESWATER OUTSUPPLY AIRDUCT FLANGESRETURN AIRDUCT FLANGESCONDENSATE DRAIN**WATER INRIGHT HAND RETURNJKLAALEF

Page 5 - Model number nomenclature

1350PTH,PTV 024-070 CORNER WEIGHTS* Front is control box end.LEGEND AND NOTES FOR PAGES 14-23LEGEND NOTES:1. Interpolation is permissible; extrapolati

Page 6 - ARI/ISO capacity ratings

1450PTH,PTV024650 CFM AT 0.34-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/wb)

Page 7 - Physical data

1550PTH,PTV024825 CFM AT 0.23-in. ESP — FULL LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/wb)

Page 8 - Options and accessories

1650PTH,PTV036800 CFM AT 0.58-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/wb)

Page 9 - Dimensions

1750PTH,PTV0361,100 CFM AT 0.25-in. ESP — FULL LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 10 - Dimensions (cont)

1850PTH,PTV0481,300 CFM AT 0.27-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 11

1950PTH,PTV0481,600 CFM AT 0.60-in. ESP — FULL LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 12

2tios) to 37.0 and heating COPs (Coeffi-ciency of Performance) to 6.5. All efficiencies stated are in accordance with standard conditions under ISO (I

Page 13

2050PTH,PTV0601,600 CFM AT 0.60-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 14 - Performance data

2150PTH,PTV0602,000 CFM AT 0.60-in. ESP — FULL LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 15 - Operation Not Recommended

2250PTH,PTV0701,850 CFM AT 0.60-in. ESP — PART LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 16 - Performance data (cont)

2350PTH,PTV0702,350 CFM AT 0.60-in. ESP — FULL LOADCOOLINGHEATINGEntering Fluid Temp (F)Water Flow (GPM)Pressure Drop PSI (FOH)Entering Air Temp (db/w

Page 17

24ANTIFREEZE CORRECTION TABLELEGENDCONSTANT TORQUE MOTOR BLOWER PERFORMANCE DATALEGEND— — Operation Not RecommendedANTIFREEZETYPEANTIFREEZE %COOLING H

Page 18

25ECM CONSTANT CFM MOTOR BLOWER PERFORMANCE DATALEGEND— — Operation Not Recommended50PTH, PTV UNITSFANSPEEDRATEDAIRFLOW(Cfm)ADJUSTMENT TAPAIRFLOW (Cfm

Page 19

2650PTH,PTV SOUND DATAUNIT SIZE LoadOctave Band Sound Power Levels dB, re 10-12 WattsCenter Frequency - HzA weighted overall (dBA)A weighted overall (

Page 20

2750PTH,PTV BLOWER MOTOR ELECTRICAL DATALEGEND50PTH,PTV UNITS WITH EH OPTION - CONSTANT TORQUE MOTOR ELECTRICAL DATALEGENDUNIT SIZE COMPRESSORRATED V

Page 21

2850PTH,PTV UNITS WITH ELECTRIC HEAT OPTION - CONSTANT AIRFLOW ECM MOTOR ELECTRICAL DATALEGENDUNIT SIZE EH RATED kW STAGEHEATER WATTS HEATER AMPSMOTO

Page 22

29Aquazone™ water source heat pump products are availablein a flexible, efficient array of models, which can be used inall types of water loop, ground

Page 23

3Puron® refrigerant (R410-A)Puron refrigerant (R-410A) is a non-chlorine based enviromentally bal-anced, non-ozone depleting refriger-ant. Puron refri

Page 24

30loop of pipe inserted into a hole. The hole is back-filled andgrouted after the pipe is inserted. The completed loop isconcealed below ground. The n

Page 25 - — — Operation Not Recommended

31WATER QUALITY GUIDELINESLEGEND*Heat exchanger materials considered are copper, cupronickel, 304 SS(stainless steel), 316 SS, titanium.†Closed recirc

Page 26

32Acoustical designSound power levels represent the sound as it is producedby the source, the WSHP unit, with no regard to attenua-tion between the so

Page 27 - Electrical data

33Vertical unitsAll guidelines established for horizontal units also apply forvertical units. In addition, since vertical units tend to be in-stalled

Page 28 - Electrical data (cont)

34Two-Stage Water Source Heat Pumps withPuron® Refrigerant (R-410A)HVAC Guide SpecificationsSize Range: 18,500 to 78,700 BtuhCooling Capacity14,400 to

Page 29 - Application data

35E. Factory-Installed Wiring:All factory-installed wiring passing through factoryknockouts and openings shall be protected fromsheet metal edges at o

Page 30 - Application data (cont)

368. Activation of any safety device shall preventcompressor operation via a lockout circuit. Thelockout circuit shall be reset at the thermostator at

Page 34 - Guide specifications

4continuous seconds of overflow is rec-ognized as a fault by the sensor.High and low voltage protection — Safety protection for excessive or low volta

Page 35

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Pg 4

Page 36 - Guide specifications (cont)

5Aquazone™ Two-Stage Water Source HeatPump with Puron Refrigerant (R-410A)®024 – 2036 – 3048 – 4060 – 5070 – 6B – Right End Constant TorqueE

Page 37

650PTH, 50PTV FULL LOAD APPLICATIONSLEGEND NOTES:1. A brine-to-air heat pump using a brine solution circulating through a subsurfacepiping loop functi

Page 38

7PHYSICAL DATA — 50PTH, PTV 024-070 UNITSLEGENDUNIT 50PTH, PTV 024 036 048 060 070COMPRESSOR ScrollREFRIGERANT CHARGE VT (oz) 58 98 88 110 114REFRIGER

Page 39

8Factory-installed optionsCupronickel heat exchangers are available for highercorrosion protection for applications such as open tower,geothermal, etc

Page 40 - Replaces: NEW

9**50PTH024-070 UNITS SUPPLY AIR CONFIGURATION - END BLOWDimensions