DETAILED COOLING CAPACITIES CONTINUED
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES deg F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
To t a l Sens‡ To t a l Sens‡ To t a l Sens‡ To t a l Sens‡ To t a l Sens‡ To t a l Sens‡
25HBA360A30 Outdoor Section With FY4ANF060 Indoor Section
1750
72 71.08 36.09 4.41 67.69 34.77 4.86 64.09 33.39 5.36 60.33 31.96 5.90 56.30 30.45 6.50 51.84 28.81 7.14
67 65.19 45.05 4.36 62.05 43.69 4.81 58.73 42.27 5.30 55.30 40.82 5.85 51.61 39.29 6.44 47.57 37.62 7.09
63 60.79 43.67 4.31 57.85 42.31 4.76 54.78 40.90 5.26 51.57 39.45 5.81 48.15 37.91 6.40 44.41 36.26 7.05
62 59.61 53.90 4.30 56.75 52.49 4.75 53.77 51.00 5.25 50.69 49.41 5.80 47.50 47.50 6.40 45.90 45.90 6.36
57 57.48 57.48 4.28 55.20 55.20 4.74 52.79 52.79 5.24 50.24 50.24 5.79 47.49 47.49 6.40 44.42 44.42 7.06
2000
72 72.12 37.62 4.54 68.55 36.26 4.99 64.87 34.89 5.48 60.98 33.44 6.03 56.80 31.91 6.62 52.19 30.25 7.26
67 66.24 47.72 4.48 62.96 46.34 4.93 59.50 44.89 5.43 55.93 43.42 5.97 52.11 41.85 6.57 47.93 40.14 7.21
63 61.83 46.19 4.44 58.77 44.80 4.89 55.56 43.36 5.38 52.22 41.88 5.93 48.67 40.31 6.53 44.80 38.60 7.18
62 60.73 57.58 4.43 57.79 56.05 4.88 54.77 54.33 5.38 51.88 51.88 5.93 48.94 48.94 6.53 47.37 47.37 6.51
57 59.63 59.63 4.42 57.18 57.18 4.87 54.60 54.60 5.38 51.89 51.89 5.93 48.94 48.94 6.53 45.66 45.66 7.19
2250
72 72.83 39.05 4.66 69.16 37.69 5.11 65.40 36.31 5.61 61.39 34.85 6.15 57.10 33.30 6.74 52.35 31.61 7.37
67 66.96 50.26 4.61 63.58 48.86 5.06 60.01 47.39 5.55 56.35 45.89 6.09 52.43 44.28 6.69 48.14 42.52 7.33
63 62.58 48.57 4.56 59.40 47.16 5.01 56.09 45.69 5.51 52.66 44.18 6.05 49.01 42.56 6.65 45.05 40.80 7.30
62 61.68 60.83 4.56 58.79 58.79 5.01 56.05 56.05 5.51 53.19 53.19 6.06 50.08 50.08 6.66 46.62 46.62 7.31
57 61.37 61.37 4.55 58.79 58.79 5.01 56.06 56.06 5.51 53.19 53.19 6.06 50.08 50.08 6.66 46.62 46.62 7.31
Cooling Indoor Model Capacity Power Furnace Model
*FY4ANB060 1.00 1.00
FV4BNB006 1.01 0.95
FX4CN(B,F)060 1.01 0.91
CAP**6021A** 0.99 0.99
CAP**6024A** 1.01 1.01
CNPH*6024A** 1.00 1.00
CNPV*6024A** 1.00 1.00
CSPH*6012A** 1.01 1.01
CAP**6021A** 0.97 0.94 58CV(A,X)110---20
CNPH*6024A** 0.98 0.95 58CV(A,X)110--- 20
CSPH*6012A** 0.99 0.96 58CV(A,X)110---20
CAP**6024A** 0.99 0.93 58CV(A,X)135---22
CNPH*6024A** 0.98 0.95 58CV(A,X)135--- 22
CNPV*6024A** 0.98 0.95 58CV(A,X)135--- 22
CSPH*6012A** 0.99 0.93 58CV(A,X)135---22
CAP**6024A** 0.99 0.93 58CV(A,X)155---22
CNPH*6024A** 0.99 0.93 58CV(A,X)155--- 22
CNPV*6024A** 0.99 0.93 58CV(A,X)155--- 22
CSPH*6012A** 0.99 0.93 58CV(A,X)155---22
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standa rd 210/240---94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F(27_C) entering air at the indoor coil. For sensible capacities at other than 80_F(27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F(27_C), or add 835 Btu h (245 kW) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80_F(27_C).
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures a re at 80_F edb.
EWB Entering Wet Bulb