62--10828Safety-3
CAUTION
Observe proper polarity when installing battery, negative battery terminal must be grounded. Re-
verse polarity will destroy the rectifier diodes in alternator. As a precautionary measure, disconnect
positive battery terminal when charging battery in unit. Connecting charger in reverse will destroy
the rectifier diodes in alternator.
CAUTION
Under no circumstances should anyone attempt to repair the microprocessor or the Logic or Display
Boards. Should a problem develop with these components, contact your nearest Carrier Transicold
dealer for replacement.
CAUTION
Unit with R404A and POE oil, the use of inert gas brazing procedures is mandatory; otherwise com-
pressor failure will occur. For more information see Technical Procedure 98-50553-00 Inert Gas Braz-
ing
CAUTION
Use only ethylene glycol anti-freeze (with inhibitors) in system as glycol by itself will damage the
cooling system.
Always add pre-mixed 50/50 anti-freeze and water to radiator/engine. Never exceed more than a 50%
concentration of anti-freeze. Use a low silicate anti-freeze.
CAUTION
When changing oil filters, the new filters should be primed with clean oil. If the filters are not primed,
the engine may operate for a period with no oil supplied to the bearings.
CAUTION
When changing fuel filter, the new filter should be filled with clean fuel.
CAUTION
To prevent trapping liquid refrigerant in the manifold gauge set be sure set is brought to suction
pressure before disconnecting.
Page view 11