1.5 SYSTEM OPERATING CONTROLS AND
COMPONENTS
The unit is furnished with a microprocessor control
system. Once the set point is entered at the controller,
the unit will operate automatically to maintain the de-
sired temperature within very close limits. The control
system automatically selects high and low speed cool-
ing or high and low speed heating as necessary to main-
tain the desired temperature.
Units also have a auto start/stop feature. Auto start/stop
operation provides automatic cycling of the diesel en-
gine or standby motor, which in turn offers an energy
efficient alternative to continuous operation.
1.5.1 Switches And Controls
Manual control switches are located on the side of the
electrical box. Components required for monitoring and
controlling the diesel engine and refrigeration system
are located on the engine, compressor or system piping.
1. RUN/STOP Switch (RSS)
This switch controls the supply of power to the micropro-
cessor and cab command. The switch is placed in the
ON position to allow manual or automatic unit operation.
With the switch in the OFF position, the unit will be shut
down and neither manual or automatic starting is al-
lowed.
2. Manual Glow/Crank Switch (MGC) If Equipped
If the unit is equipped with a Manual Glow/Crank Switch,
it is a three--position switch. This switch is held in the
GLOW position to energize the glow plugs and pre-heat
the combustion chamber. The switch is moved to the
CRANK position to manually engage the engine starter.
When the switch is released, it returns to the middle
position to de-energize both components.
3. Oil Pressure Safety Switch (OP)
This switch will automatically stop the engine upon loss
of oil pressure. The switch is located on the side of the
engine.
4. Water Temperature Sensor (WTS)
The microprocessor will stop the unit when this sensor
signals a high water temperature condition. The sensor
is located on the engine cylinder head.
5. High Pressure Cutout Switch (HP1)
This switch will automatically stop the engine when
compressor discharge pressure exceeds the set point.
The switch is located on the compressor cylinder head.
6. High Pressure Switch (HP2) (850 Only)
This switch is used to unload the compressor in high
ambient conditions.
7. Compressor Discharge Temperature Sensor (CDT)
(except for 850)
The microprocessor will stop the unit when this sensor
signals a high discharge temperature condition. The
sensor is located on the compressor center head.
8. Compressor Suction Pressure Transducer (SPT)
The Compressor Suction Pressure Transducer signal is
used by the microprocessor in the compressor protec-
tion logic to protect the compressor under excessive
suction pressure conditions and under excessively low
suction pressure conditions. The sensor is located on
the compressor body for all units except 850. It is lo-
cated in the suction line for 850 units.
9. Ambient Temperature Sensor (ATS) (950 Only)
The Ambient Temperature Sensor signal is used by the
microprocessor in the compressor protection logic to
determine expected conditions. It is located between
the condenser and the front grille.
10. Temperature control sensors
Box temperature is controlled by one or two sensors:
SRAS: Measures return air to the evaporator
SSAS (optional): Measures supply air to the evapora-
tor and is also used in heat option kits as an overtem-
perature safety sensor.