Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53330002-01 Printed in U.S.A. Form 33CS-58SI Pg 1 4-07 Replaces: 33CS-57SI
Book 1 4
Tab 11a 13a
Installation, Start-Up and
Configuration Instructions
Part Number 33CSPREMLK
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PremierLink Controller Hardware. . . . . . . . . . . . . . . . . 2
Field-Supplied Hardware . . . . . . . . . . . . . . . . . . . . . . . . . 2
SPACE TEMPERATURE (SPT) SENSOR
SUPPLY AIR TEMPERATURE (SAT) SENSOR
INDOOR AIR QUALITY CO
2
SENSOR
OUTDOOR AIR QUALITY CO
2
SENSOR
RELATIVE HUMIDITY SENSOR
OUTDOOR AIR TEMPERATURE SENSOR
OUTDOOR AIR ENTHALPY SWITCH/RECEIVER
FILTER SWITCH
Mount PremierLink Control. . . . . . . . . . . . . . . . . . . . . . . 3
•LOCATION
MOUNTING
PremierLink Controller Inputs and Outputs . . . . . . 3
Control Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Install Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SPACE TEMPERATURE (SPT) SENSOR
INSTALLATION
SUPPLY AIR TEMPERATURE (SAT) SENSOR
INSTALLATION
INDOOR AIR QUALITY CO
2
SENSOR
INSTALLATION
OUTDOOR AIR QUALITY CO
2
SENSOR
INSTALLATION
HUMIDITY SENSOR (WALL-MOUNTED) INSTAL-
LATION
OUTDOOR AIR TEMPERATURE SENSOR
FACTORY-INSTALLED CONTROLLER
Connect Discrete Inputs . . . . . . . . . . . . . . . . . . . . . . . . 14
Connect to CCN Communication Bus . . . . . . . . . . . 16
COMMUNICATIONS BUS WIRE SPECIFICATIONS
Enthalpy/Switch Receiver . . . . . . . . . . . . . . . . . . . . . . . 18
OUTDOOR ENTHALPY CONTROL
•DIFFERENTIAL ENTHALPY CONTROL
Enthalpy Sensors and Control . . . . . . . . . . . . . . . . . . 20
OUTDOOR AIR ENTHALPY SENSOR/
ENTHALPY CONTROLLER
RETURN AIR ENTHALPY SENSOR
Economizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Q769B ADAPTER
Q769C ADAPTER
Economizer with 4 to 20 mA Actuator . . . . . . . . . . . 23
DRIVE DIRECTION
SWITCH SELECTION
•WIRING
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-31
Page
Perform System Check-Out . . . . . . . . . . . . . . . . . . . . . 25
Initial Operation and Test . . . . . . . . . . . . . . . . . . . . . . . 25
Sequence of Operation. . . . . . . . . . . . . . . . . . . . . . . . . . 25
THERMOSTAT MODE
CCN SENSOR MODE
CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-49
Points Display Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Thermostat Control Input Screen. . . . . . . . . . . . . . . . 34
Alarm Service Configuration Screen . . . . . . . . . . . . 34
Controller Identification Screen . . . . . . . . . . . . . . . . . 35
Holiday Configuration Screen . . . . . . . . . . . . . . . . . . . 35
Occupancy Configuration Screen . . . . . . . . . . . . . . . 35
Set Point Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Service Configuration Selection Screen. . . . . . . . . 37
PremierLink Configuration Screen . . . . . . . . . . . . . . 41
Occupancy Maintenance Screen . . . . . . . . . . . . . . . . 44
Primary Maintenance Screen. . . . . . . . . . . . . . . . . . . . 45
System Pilot Maintenance Table. . . . . . . . . . . . . . . . . 48
System Pilot Alternate Maintenance Table. . . . . . . 48
SAFETY CONSIDERATIONS
SAFETY NOTE
Air-conditioning equipment will provide safe and reliable
service when operated within design specifications. The
equipment should be operated and serviced only by autho-
rized personnel who have a thorough knowledge of system
operation, safety devices and emergency procedures.
Good judgement should be used in applying any manufac-
turers instructions to avoid injury to personnel or damage to
equipment and property.
Disconnect all power to the unit before performing mainte-
nance or service. Unit may automatically start if power is
not disconnected. Electrical shock and personal injury
could result.
An individual field-supplied 24-vac power transformer is
recommended for each PremierLink controller. If the unit
transformer is used but does not have enough power, dam-
age to equipment may result. The field-supplied trans-
former must be less than 100 VA to meet UL (Underwriters
Laboratories) Class 2.
PREMIERLINK™
Retrofit Rooftop Controller
Version 2.x