Carrier 33ZCVAVTRM Specifications Page 185

  • Download
  • Add to my manuals
  • Print
  • Page
    / 316
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 184
3
Wiring connections
Field wiring is 18 to 22 AWG (American Wire Gage). The
VVT zone controller is a NEC (National Electronic Code)
Class 2 rated device.
Inputs
Space temperature sensor
T55/T56 wall-mounted space temperature sensor
interface
T56 space temperature set point reset (slide potentiom-
eter)
Optional supply air temperature sensor (required for
reheat and stand-alone operation)
Optional primary air temperature sensor (one required
per system that does not utilize a linkage compatible air
source)
•Optional CO
2
sensor
Optional relative humidity sensor (for monitoring only)
Optional remote occupancy contact input
Outputs
Integrated factory-wired pressure dependent damper
actuator
Heating (requires VVT Zone Controller Option Board
33ZCOPTBRD-01)
Two-position hot water
One to three stages of heat
Modulating hot water valve
Combination radiant/ducted heat stages
Terminal fan (requires VVT Zone Controller Option
Board 33ZCOPTBRD-01)
Damper position output (0 to 10v) for linked dampers
Power supply
The power supply is 24 vac ± 10% at 40 va (50/60 Hz).
Communications
The number of controllers is limited to 128 devices maxi-
mum, with a limit of 8 systems (Linkage Coordinator con-
figured for at least 2 zones). Bus length may not exceed
4000 ft (1219 m), with no more than 60 devices on any
1000 ft (305 m) section. Optically isolated RS-485 repeat-
ers are required every 1000 ft (305 m).
At 19,200 and 38,400 baud, the number of controllers
is limited to 128 maximum, with no limit on the number of
Linkage Coordinators. Bus length may not exceed 1000 ft
(305 m).
Environmental ratings
Operating Temperature. . . . .32 F to 131 F (0° C to 55 C)
Storage Temperature . . . . . .32 F to 158 F (0° C to 70 C)
Operating Humidity . . . . . . 10% to 95%, non-condensing
Storage Humidity . . . . .10% to 41% at 158 F, condensing
Power consumption
The power requirement sizing allows for accessory water
valves and for the fan contactor. Water valves are limited to
15 va. The fan contactor is limited to 10 va (holding).
Vibration
Performance Vibration:
1.5 G measured at 20 to 300 Hz
Corrosion
Office environment. Indoor use only.
Approvals
•NEC Class 2
UL 916-PAZX and UL 873
Conforms to requirements per European Consortium
standards EN50081-1 (CISPR 22, Class B) and
EN50082-1 (IEC 801-2, IEC 801-3, and IEC 801-4)
for CE mark labeling
UL94-5V (actuator)
Accessories
Supply air temperature sensor — The 33ZCSENSAT
supply air temperature sensor is required for heating appli-
cations or stand-alone operation. The sensor has an oper-
ating range of –40 to 245 F (–40 to 118 C) and includes a
6-in. stainless steel probe and cable.
Duct air temperature sensor The 33ZCSENDAT
Duct Air Temperature Sensor is required for cooling only
applications on non-33ZC dampers. The sensor is used for
supply air monitoring. The sensor has an operating range
of –40 to 245 F (–40 to 118 C) and includes a mounting
grommet and 75-in. cable.
Primary air temperature sensor — The 33ZCSENPAT
Primary Air Temperature sensor is required on a linkage
coordinator Zone Controller if the Zone Controller is not
using a Carrier network, linkage compatible air source.
The sensor is used to monitor the equipment’s supply-air
temperature. The temperature is broadcast to the system
Zone Controllers which receive information from the mas-
ter. The sensor has an operating range of –40 to 245 F
(–40 to 118 C) and includes a 6-in. stainless steel probe
with conduit box.
Space temperature sensor with override button —
The 33ZCT55SPT Space Temperature Sensor with Over-
ride Button is required for all applications. The space tem-
perature sensor monitors room temperature, which is used
by the Zone Controller to determine the amount of condi-
tioned air that is allowed into the space.
Space temperature sensor with override button
and set point adjustment — The 33ZCT56SPT Space
Temperature Sensor with Override Button and Set Point
Adjustment can be used in place of the 33ZCT55SPT
space temperature sensor if local set point adjustment is
required. A space temperature sensor is required for all
applications. The space temperature sensor monitors
room temperature, which is used by the Zone Controller to
determine the amount of conditioned air that is allowed
into the space. The set point adjustment bar is configurable
Specifications
Page view 184
1 2 ... 180 181 182 183 184 185 186 187 188 189 190 ... 315 316

Comments to this Manuals

No comments