Carrier 33ZCVAVTRM Specifications Page 188

  • Download
  • Add to my manuals
  • Print
  • Page
    / 316
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 187
2
ability to control exhaust fan based
on economizer or occupancy on
2 stage heat units
ability to control reversing valve on
heat pump units
provides temperature compensated
start of heating or cooling to achieve
set point by the start of the sched-
uled occupied time
provides alarms for analog
temperature input(s) out of range
provides alarm for space tempera-
ture deviation from desired set point
adjustable filter maintenance timer
allows manual and system over-
rides of selected input/output
channels
supports CCN remote timed
override, set point adjustment and
manual fan speed override
provides Broadcast Acknowledger
capability for CCN (configuration)
conforms to the general require-
ments for CCN devices
supports Navigator and Scrolling
Marquee Display and alarms
modulates control of economizer to
assist mechanical cooling without
adversely affecting compressor
performance
provides ventilation monitoring with
optional CO
2
ventilation sensor
compatible with T55 space sensor
and T56 space sensor with set point
adjustment, timed override and
service port jack
compatibility with T58 communi-
cating sensor provides set point
adjustment, timed override, force
fan, and read equipment mode
support a local or global occupancy
schedule or remote start input
status to determine occupancy
Features/Benefits
Available for wide range of
rooftop applications
The PremierLink™ controller is avail-
able as a field retrofit application and
can control one or several rooftop units
with (multiple controllers) from 3 to
25 tons. In addition, it has an integrated
economizer controller that eliminates
the need for a separate circuit board.
The PremierLink controller can be
installed on the following Carrier roof-
top units: 48/50HJ (3 to 12
1
/
2
tons),
48TF/50TFF (3 to 12
1
/
2
tons), and
48/50TJ (12
1
/
2
to 25 tons). Other
Carrier equipment and non-Carrier
equipment can also be controlled by
PremierLink controller. Contact Carrier
Factory Sales representative for more
information.
Flexibility for every application
The PremierLink controller is an ad-
vanced microprocessor-based control.
PremierLink is precision controlled to
send heating and cooling only when
needed, reducing energy use and oper-
ating costs.
Carrier Linkage Thermostat
compatibility
When connected to a Carrier Linkage
Thermostat, the PremierLink controller
can use occupancy schedules, zone tem-
perature, and set points from the ther-
mostat. The PremierLink controller
provides the thermostat with the unit’s
operating mode and supply air tempera-
ture for local display at the thermostat.
When used with the Linkage Ther-
mostat, the PremierLink controller pro-
vides local space temperature sensing,
(remote space temperature sensing and
averaging with up to 3 optional remote
room sensors), occupied and unoccu-
pied heat and cool set points, occu-
pancy scheduling with up to 8 time
periods, 12 holiday periods, network
time broadcast, occupied set point
range limiting, temperature compen-
sated start, and global occupancy. A sin-
gle Linkage Thermostat will have the
ability to interface with up to 8 rooftop
controls serving a single zone with the
ability to unlink if communications to
the linkage thermostat are lost.
Fast and reliable system moni-
toring with Navigator
Carrier’s unique, hand-held diagnostic
tool, Navigator, can be used with the
PremierLink controller. Instant access to
detailed information is provided to tech-
nicians. Access is available via an RJ-11
connection or a 3-wire connection to
the communication bus.
Navigator offers flexibility for fast
service. Technicians can monitor roof-
top operation from the rooftop’s main
control panel. Additional hardware or
controller configuration is required for
Navigator applications.
Additional control features
The PremierLink controller provides
additional control features such as
Occupied/Unoccupied scheduling
initialized via the network. The Premier-
Link controller offers override invoked
from a wall sensor during unoccupied
hours from 1 to 4 hours in 1-hour
increments.
The PremierLink controller offers
ventilation monitoring with an optional
CO
2
ventilation sensor. The CO
2
venti-
lation sensor measures the amount of
ventilation needed by the space and a
proportional integral derivative loop
(PID) calculation makes adjustments to
the economizer minimum position dur-
ing occupied operation. The indoor
CO
2
will be compared to an outdoor
CO
2
reference before making adjust-
ments to the economizer minimum
position.
Using a space sensor with set point
adjustment, timed override and service
port jack, the PremierLink controller
will provide intelligent compressor stag-
ing and economizer operation.
Modulating control of the economizer
will assist mechanical cooling without
adversely affecting compressor perfor-
mance. Economizer assisted cooling is
determined from a comparison of space
temperature, outside air temperature
and an enthalpy switch input. The
switch input can also be used for differ-
ential enthalpy input, meeting ASHRAE
Standard 90.1.
The T58 Communicating Space tem-
perature sensor with service port jack
provides set point adjustment, timed
override, force fan and read equipment
mode and measures and maintains
room temperature by communicating
with the PremierLink controller.
Simple mounting and ease of
installation
The PremierLink controller has an inte-
grated plastic cover with secured with
two plastic tabs that can be removed for
ease of installation.
For ease of installation, PremierLink
controller is provided with removable
Molex connectors which include pigtails
for easy installation to unit or sensors
using spade connectors or wire nuts.
The removable connectors are designed
so that they can be inserted one way so
as to prevent installation errors. The
PremierLink controller also provides an
RJ-11 modular phone jack for the Net-
work Service Tool connection to the
module via the Carrier Comfort Net-
work (CCN) communications.
Page view 187
1 2 ... 183 184 185 186 187 188 189 190 191 192 193 ... 315 316

Comments to this Manuals